123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519520521522523524525526527528529530531532533534535536537538539540 |
- #pragma once
- // MESSAGE GENERATOR_STATUS PACKING
- #define MAVLINK_MSG_ID_GENERATOR_STATUS 373
- typedef struct __mavlink_generator_status_t {
- uint64_t status; /*< Status flags.*/
- float battery_current; /*< [A] Current into/out of battery. Positive for out. Negative for in. NaN: field not provided.*/
- float load_current; /*< [A] Current going to the UAV. If battery current not available this is the DC current from the generator. Positive for out. Negative for in. NaN: field not provided*/
- float power_generated; /*< [W] The power being generated. NaN: field not provided*/
- float bus_voltage; /*< [V] Voltage of the bus seen at the generator, or battery bus if battery bus is controlled by generator and at a different voltage to main bus.*/
- float bat_current_setpoint; /*< [A] The target battery current. Positive for out. Negative for in. NaN: field not provided*/
- uint32_t runtime; /*< [s] Seconds this generator has run since it was rebooted. UINT32_MAX: field not provided.*/
- int32_t time_until_maintenance; /*< [s] Seconds until this generator requires maintenance. A negative value indicates maintenance is past-due. INT32_MAX: field not provided.*/
- uint16_t generator_speed; /*< [rpm] Speed of electrical generator or alternator. UINT16_MAX: field not provided.*/
- int16_t rectifier_temperature; /*< [degC] The temperature of the rectifier or power converter. INT16_MAX: field not provided.*/
- int16_t generator_temperature; /*< [degC] The temperature of the mechanical motor, fuel cell core or generator. INT16_MAX: field not provided.*/
- } mavlink_generator_status_t;
- #define MAVLINK_MSG_ID_GENERATOR_STATUS_LEN 42
- #define MAVLINK_MSG_ID_GENERATOR_STATUS_MIN_LEN 42
- #define MAVLINK_MSG_ID_373_LEN 42
- #define MAVLINK_MSG_ID_373_MIN_LEN 42
- #define MAVLINK_MSG_ID_GENERATOR_STATUS_CRC 117
- #define MAVLINK_MSG_ID_373_CRC 117
- #if MAVLINK_COMMAND_24BIT
- #define MAVLINK_MESSAGE_INFO_GENERATOR_STATUS { \
- 373, \
- "GENERATOR_STATUS", \
- 11, \
- { { "status", NULL, MAVLINK_TYPE_UINT64_T, 0, 0, offsetof(mavlink_generator_status_t, status) }, \
- { "generator_speed", NULL, MAVLINK_TYPE_UINT16_T, 0, 36, offsetof(mavlink_generator_status_t, generator_speed) }, \
- { "battery_current", NULL, MAVLINK_TYPE_FLOAT, 0, 8, offsetof(mavlink_generator_status_t, battery_current) }, \
- { "load_current", NULL, MAVLINK_TYPE_FLOAT, 0, 12, offsetof(mavlink_generator_status_t, load_current) }, \
- { "power_generated", NULL, MAVLINK_TYPE_FLOAT, 0, 16, offsetof(mavlink_generator_status_t, power_generated) }, \
- { "bus_voltage", NULL, MAVLINK_TYPE_FLOAT, 0, 20, offsetof(mavlink_generator_status_t, bus_voltage) }, \
- { "rectifier_temperature", NULL, MAVLINK_TYPE_INT16_T, 0, 38, offsetof(mavlink_generator_status_t, rectifier_temperature) }, \
- { "bat_current_setpoint", NULL, MAVLINK_TYPE_FLOAT, 0, 24, offsetof(mavlink_generator_status_t, bat_current_setpoint) }, \
- { "generator_temperature", NULL, MAVLINK_TYPE_INT16_T, 0, 40, offsetof(mavlink_generator_status_t, generator_temperature) }, \
- { "runtime", NULL, MAVLINK_TYPE_UINT32_T, 0, 28, offsetof(mavlink_generator_status_t, runtime) }, \
- { "time_until_maintenance", NULL, MAVLINK_TYPE_INT32_T, 0, 32, offsetof(mavlink_generator_status_t, time_until_maintenance) }, \
- } \
- }
- #else
- #define MAVLINK_MESSAGE_INFO_GENERATOR_STATUS { \
- "GENERATOR_STATUS", \
- 11, \
- { { "status", NULL, MAVLINK_TYPE_UINT64_T, 0, 0, offsetof(mavlink_generator_status_t, status) }, \
- { "generator_speed", NULL, MAVLINK_TYPE_UINT16_T, 0, 36, offsetof(mavlink_generator_status_t, generator_speed) }, \
- { "battery_current", NULL, MAVLINK_TYPE_FLOAT, 0, 8, offsetof(mavlink_generator_status_t, battery_current) }, \
- { "load_current", NULL, MAVLINK_TYPE_FLOAT, 0, 12, offsetof(mavlink_generator_status_t, load_current) }, \
- { "power_generated", NULL, MAVLINK_TYPE_FLOAT, 0, 16, offsetof(mavlink_generator_status_t, power_generated) }, \
- { "bus_voltage", NULL, MAVLINK_TYPE_FLOAT, 0, 20, offsetof(mavlink_generator_status_t, bus_voltage) }, \
- { "rectifier_temperature", NULL, MAVLINK_TYPE_INT16_T, 0, 38, offsetof(mavlink_generator_status_t, rectifier_temperature) }, \
- { "bat_current_setpoint", NULL, MAVLINK_TYPE_FLOAT, 0, 24, offsetof(mavlink_generator_status_t, bat_current_setpoint) }, \
- { "generator_temperature", NULL, MAVLINK_TYPE_INT16_T, 0, 40, offsetof(mavlink_generator_status_t, generator_temperature) }, \
- { "runtime", NULL, MAVLINK_TYPE_UINT32_T, 0, 28, offsetof(mavlink_generator_status_t, runtime) }, \
- { "time_until_maintenance", NULL, MAVLINK_TYPE_INT32_T, 0, 32, offsetof(mavlink_generator_status_t, time_until_maintenance) }, \
- } \
- }
- #endif
- /**
- * @brief Pack a generator_status message
- * @param system_id ID of this system
- * @param component_id ID of this component (e.g. 200 for IMU)
- * @param msg The MAVLink message to compress the data into
- *
- * @param status Status flags.
- * @param generator_speed [rpm] Speed of electrical generator or alternator. UINT16_MAX: field not provided.
- * @param battery_current [A] Current into/out of battery. Positive for out. Negative for in. NaN: field not provided.
- * @param load_current [A] Current going to the UAV. If battery current not available this is the DC current from the generator. Positive for out. Negative for in. NaN: field not provided
- * @param power_generated [W] The power being generated. NaN: field not provided
- * @param bus_voltage [V] Voltage of the bus seen at the generator, or battery bus if battery bus is controlled by generator and at a different voltage to main bus.
- * @param rectifier_temperature [degC] The temperature of the rectifier or power converter. INT16_MAX: field not provided.
- * @param bat_current_setpoint [A] The target battery current. Positive for out. Negative for in. NaN: field not provided
- * @param generator_temperature [degC] The temperature of the mechanical motor, fuel cell core or generator. INT16_MAX: field not provided.
- * @param runtime [s] Seconds this generator has run since it was rebooted. UINT32_MAX: field not provided.
- * @param time_until_maintenance [s] Seconds until this generator requires maintenance. A negative value indicates maintenance is past-due. INT32_MAX: field not provided.
- * @return length of the message in bytes (excluding serial stream start sign)
- */
- static inline uint16_t mavlink_msg_generator_status_pack(uint8_t system_id, uint8_t component_id, mavlink_message_t* msg,
- uint64_t status, uint16_t generator_speed, float battery_current, float load_current, float power_generated, float bus_voltage, int16_t rectifier_temperature, float bat_current_setpoint, int16_t generator_temperature, uint32_t runtime, int32_t time_until_maintenance)
- {
- #if MAVLINK_NEED_BYTE_SWAP || !MAVLINK_ALIGNED_FIELDS
- char buf[MAVLINK_MSG_ID_GENERATOR_STATUS_LEN];
- _mav_put_uint64_t(buf, 0, status);
- _mav_put_float(buf, 8, battery_current);
- _mav_put_float(buf, 12, load_current);
- _mav_put_float(buf, 16, power_generated);
- _mav_put_float(buf, 20, bus_voltage);
- _mav_put_float(buf, 24, bat_current_setpoint);
- _mav_put_uint32_t(buf, 28, runtime);
- _mav_put_int32_t(buf, 32, time_until_maintenance);
- _mav_put_uint16_t(buf, 36, generator_speed);
- _mav_put_int16_t(buf, 38, rectifier_temperature);
- _mav_put_int16_t(buf, 40, generator_temperature);
- memcpy(_MAV_PAYLOAD_NON_CONST(msg), buf, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN);
- #else
- mavlink_generator_status_t packet;
- packet.status = status;
- packet.battery_current = battery_current;
- packet.load_current = load_current;
- packet.power_generated = power_generated;
- packet.bus_voltage = bus_voltage;
- packet.bat_current_setpoint = bat_current_setpoint;
- packet.runtime = runtime;
- packet.time_until_maintenance = time_until_maintenance;
- packet.generator_speed = generator_speed;
- packet.rectifier_temperature = rectifier_temperature;
- packet.generator_temperature = generator_temperature;
- memcpy(_MAV_PAYLOAD_NON_CONST(msg), &packet, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN);
- #endif
- msg->msgid = MAVLINK_MSG_ID_GENERATOR_STATUS;
- return mavlink_finalize_message(msg, system_id, component_id, MAVLINK_MSG_ID_GENERATOR_STATUS_MIN_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_CRC);
- }
- /**
- * @brief Pack a generator_status message
- * @param system_id ID of this system
- * @param component_id ID of this component (e.g. 200 for IMU)
- * @param status MAVLink status structure
- * @param msg The MAVLink message to compress the data into
- *
- * @param status Status flags.
- * @param generator_speed [rpm] Speed of electrical generator or alternator. UINT16_MAX: field not provided.
- * @param battery_current [A] Current into/out of battery. Positive for out. Negative for in. NaN: field not provided.
- * @param load_current [A] Current going to the UAV. If battery current not available this is the DC current from the generator. Positive for out. Negative for in. NaN: field not provided
- * @param power_generated [W] The power being generated. NaN: field not provided
- * @param bus_voltage [V] Voltage of the bus seen at the generator, or battery bus if battery bus is controlled by generator and at a different voltage to main bus.
- * @param rectifier_temperature [degC] The temperature of the rectifier or power converter. INT16_MAX: field not provided.
- * @param bat_current_setpoint [A] The target battery current. Positive for out. Negative for in. NaN: field not provided
- * @param generator_temperature [degC] The temperature of the mechanical motor, fuel cell core or generator. INT16_MAX: field not provided.
- * @param runtime [s] Seconds this generator has run since it was rebooted. UINT32_MAX: field not provided.
- * @param time_until_maintenance [s] Seconds until this generator requires maintenance. A negative value indicates maintenance is past-due. INT32_MAX: field not provided.
- * @return length of the message in bytes (excluding serial stream start sign)
- */
- static inline uint16_t mavlink_msg_generator_status_pack_status(uint8_t system_id, uint8_t component_id, mavlink_status_t *_status, mavlink_message_t* msg,
- uint64_t status, uint16_t generator_speed, float battery_current, float load_current, float power_generated, float bus_voltage, int16_t rectifier_temperature, float bat_current_setpoint, int16_t generator_temperature, uint32_t runtime, int32_t time_until_maintenance)
- {
- #if MAVLINK_NEED_BYTE_SWAP || !MAVLINK_ALIGNED_FIELDS
- char buf[MAVLINK_MSG_ID_GENERATOR_STATUS_LEN];
- _mav_put_uint64_t(buf, 0, status);
- _mav_put_float(buf, 8, battery_current);
- _mav_put_float(buf, 12, load_current);
- _mav_put_float(buf, 16, power_generated);
- _mav_put_float(buf, 20, bus_voltage);
- _mav_put_float(buf, 24, bat_current_setpoint);
- _mav_put_uint32_t(buf, 28, runtime);
- _mav_put_int32_t(buf, 32, time_until_maintenance);
- _mav_put_uint16_t(buf, 36, generator_speed);
- _mav_put_int16_t(buf, 38, rectifier_temperature);
- _mav_put_int16_t(buf, 40, generator_temperature);
- memcpy(_MAV_PAYLOAD_NON_CONST(msg), buf, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN);
- #else
- mavlink_generator_status_t packet;
- packet.status = status;
- packet.battery_current = battery_current;
- packet.load_current = load_current;
- packet.power_generated = power_generated;
- packet.bus_voltage = bus_voltage;
- packet.bat_current_setpoint = bat_current_setpoint;
- packet.runtime = runtime;
- packet.time_until_maintenance = time_until_maintenance;
- packet.generator_speed = generator_speed;
- packet.rectifier_temperature = rectifier_temperature;
- packet.generator_temperature = generator_temperature;
- memcpy(_MAV_PAYLOAD_NON_CONST(msg), &packet, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN);
- #endif
- msg->msgid = MAVLINK_MSG_ID_GENERATOR_STATUS;
- #if MAVLINK_CRC_EXTRA
- return mavlink_finalize_message_buffer(msg, system_id, component_id, _status, MAVLINK_MSG_ID_GENERATOR_STATUS_MIN_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_CRC);
- #else
- return mavlink_finalize_message_buffer(msg, system_id, component_id, _status, MAVLINK_MSG_ID_GENERATOR_STATUS_MIN_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN);
- #endif
- }
- /**
- * @brief Pack a generator_status message on a channel
- * @param system_id ID of this system
- * @param component_id ID of this component (e.g. 200 for IMU)
- * @param chan The MAVLink channel this message will be sent over
- * @param msg The MAVLink message to compress the data into
- * @param status Status flags.
- * @param generator_speed [rpm] Speed of electrical generator or alternator. UINT16_MAX: field not provided.
- * @param battery_current [A] Current into/out of battery. Positive for out. Negative for in. NaN: field not provided.
- * @param load_current [A] Current going to the UAV. If battery current not available this is the DC current from the generator. Positive for out. Negative for in. NaN: field not provided
- * @param power_generated [W] The power being generated. NaN: field not provided
- * @param bus_voltage [V] Voltage of the bus seen at the generator, or battery bus if battery bus is controlled by generator and at a different voltage to main bus.
- * @param rectifier_temperature [degC] The temperature of the rectifier or power converter. INT16_MAX: field not provided.
- * @param bat_current_setpoint [A] The target battery current. Positive for out. Negative for in. NaN: field not provided
- * @param generator_temperature [degC] The temperature of the mechanical motor, fuel cell core or generator. INT16_MAX: field not provided.
- * @param runtime [s] Seconds this generator has run since it was rebooted. UINT32_MAX: field not provided.
- * @param time_until_maintenance [s] Seconds until this generator requires maintenance. A negative value indicates maintenance is past-due. INT32_MAX: field not provided.
- * @return length of the message in bytes (excluding serial stream start sign)
- */
- static inline uint16_t mavlink_msg_generator_status_pack_chan(uint8_t system_id, uint8_t component_id, uint8_t chan,
- mavlink_message_t* msg,
- uint64_t status,uint16_t generator_speed,float battery_current,float load_current,float power_generated,float bus_voltage,int16_t rectifier_temperature,float bat_current_setpoint,int16_t generator_temperature,uint32_t runtime,int32_t time_until_maintenance)
- {
- #if MAVLINK_NEED_BYTE_SWAP || !MAVLINK_ALIGNED_FIELDS
- char buf[MAVLINK_MSG_ID_GENERATOR_STATUS_LEN];
- _mav_put_uint64_t(buf, 0, status);
- _mav_put_float(buf, 8, battery_current);
- _mav_put_float(buf, 12, load_current);
- _mav_put_float(buf, 16, power_generated);
- _mav_put_float(buf, 20, bus_voltage);
- _mav_put_float(buf, 24, bat_current_setpoint);
- _mav_put_uint32_t(buf, 28, runtime);
- _mav_put_int32_t(buf, 32, time_until_maintenance);
- _mav_put_uint16_t(buf, 36, generator_speed);
- _mav_put_int16_t(buf, 38, rectifier_temperature);
- _mav_put_int16_t(buf, 40, generator_temperature);
- memcpy(_MAV_PAYLOAD_NON_CONST(msg), buf, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN);
- #else
- mavlink_generator_status_t packet;
- packet.status = status;
- packet.battery_current = battery_current;
- packet.load_current = load_current;
- packet.power_generated = power_generated;
- packet.bus_voltage = bus_voltage;
- packet.bat_current_setpoint = bat_current_setpoint;
- packet.runtime = runtime;
- packet.time_until_maintenance = time_until_maintenance;
- packet.generator_speed = generator_speed;
- packet.rectifier_temperature = rectifier_temperature;
- packet.generator_temperature = generator_temperature;
- memcpy(_MAV_PAYLOAD_NON_CONST(msg), &packet, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN);
- #endif
- msg->msgid = MAVLINK_MSG_ID_GENERATOR_STATUS;
- return mavlink_finalize_message_chan(msg, system_id, component_id, chan, MAVLINK_MSG_ID_GENERATOR_STATUS_MIN_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_CRC);
- }
- /**
- * @brief Encode a generator_status struct
- *
- * @param system_id ID of this system
- * @param component_id ID of this component (e.g. 200 for IMU)
- * @param msg The MAVLink message to compress the data into
- * @param generator_status C-struct to read the message contents from
- */
- static inline uint16_t mavlink_msg_generator_status_encode(uint8_t system_id, uint8_t component_id, mavlink_message_t* msg, const mavlink_generator_status_t* generator_status)
- {
- return mavlink_msg_generator_status_pack(system_id, component_id, msg, generator_status->status, generator_status->generator_speed, generator_status->battery_current, generator_status->load_current, generator_status->power_generated, generator_status->bus_voltage, generator_status->rectifier_temperature, generator_status->bat_current_setpoint, generator_status->generator_temperature, generator_status->runtime, generator_status->time_until_maintenance);
- }
- /**
- * @brief Encode a generator_status struct on a channel
- *
- * @param system_id ID of this system
- * @param component_id ID of this component (e.g. 200 for IMU)
- * @param chan The MAVLink channel this message will be sent over
- * @param msg The MAVLink message to compress the data into
- * @param generator_status C-struct to read the message contents from
- */
- static inline uint16_t mavlink_msg_generator_status_encode_chan(uint8_t system_id, uint8_t component_id, uint8_t chan, mavlink_message_t* msg, const mavlink_generator_status_t* generator_status)
- {
- return mavlink_msg_generator_status_pack_chan(system_id, component_id, chan, msg, generator_status->status, generator_status->generator_speed, generator_status->battery_current, generator_status->load_current, generator_status->power_generated, generator_status->bus_voltage, generator_status->rectifier_temperature, generator_status->bat_current_setpoint, generator_status->generator_temperature, generator_status->runtime, generator_status->time_until_maintenance);
- }
- /**
- * @brief Encode a generator_status struct with provided status structure
- *
- * @param system_id ID of this system
- * @param component_id ID of this component (e.g. 200 for IMU)
- * @param status MAVLink status structure
- * @param msg The MAVLink message to compress the data into
- * @param generator_status C-struct to read the message contents from
- */
- static inline uint16_t mavlink_msg_generator_status_encode_status(uint8_t system_id, uint8_t component_id, mavlink_status_t* _status, mavlink_message_t* msg, const mavlink_generator_status_t* generator_status)
- {
- return mavlink_msg_generator_status_pack_status(system_id, component_id, _status, msg, generator_status->status, generator_status->generator_speed, generator_status->battery_current, generator_status->load_current, generator_status->power_generated, generator_status->bus_voltage, generator_status->rectifier_temperature, generator_status->bat_current_setpoint, generator_status->generator_temperature, generator_status->runtime, generator_status->time_until_maintenance);
- }
- /**
- * @brief Send a generator_status message
- * @param chan MAVLink channel to send the message
- *
- * @param status Status flags.
- * @param generator_speed [rpm] Speed of electrical generator or alternator. UINT16_MAX: field not provided.
- * @param battery_current [A] Current into/out of battery. Positive for out. Negative for in. NaN: field not provided.
- * @param load_current [A] Current going to the UAV. If battery current not available this is the DC current from the generator. Positive for out. Negative for in. NaN: field not provided
- * @param power_generated [W] The power being generated. NaN: field not provided
- * @param bus_voltage [V] Voltage of the bus seen at the generator, or battery bus if battery bus is controlled by generator and at a different voltage to main bus.
- * @param rectifier_temperature [degC] The temperature of the rectifier or power converter. INT16_MAX: field not provided.
- * @param bat_current_setpoint [A] The target battery current. Positive for out. Negative for in. NaN: field not provided
- * @param generator_temperature [degC] The temperature of the mechanical motor, fuel cell core or generator. INT16_MAX: field not provided.
- * @param runtime [s] Seconds this generator has run since it was rebooted. UINT32_MAX: field not provided.
- * @param time_until_maintenance [s] Seconds until this generator requires maintenance. A negative value indicates maintenance is past-due. INT32_MAX: field not provided.
- */
- #ifdef MAVLINK_USE_CONVENIENCE_FUNCTIONS
- static inline void mavlink_msg_generator_status_send(mavlink_channel_t chan, uint64_t status, uint16_t generator_speed, float battery_current, float load_current, float power_generated, float bus_voltage, int16_t rectifier_temperature, float bat_current_setpoint, int16_t generator_temperature, uint32_t runtime, int32_t time_until_maintenance)
- {
- #if MAVLINK_NEED_BYTE_SWAP || !MAVLINK_ALIGNED_FIELDS
- char buf[MAVLINK_MSG_ID_GENERATOR_STATUS_LEN];
- _mav_put_uint64_t(buf, 0, status);
- _mav_put_float(buf, 8, battery_current);
- _mav_put_float(buf, 12, load_current);
- _mav_put_float(buf, 16, power_generated);
- _mav_put_float(buf, 20, bus_voltage);
- _mav_put_float(buf, 24, bat_current_setpoint);
- _mav_put_uint32_t(buf, 28, runtime);
- _mav_put_int32_t(buf, 32, time_until_maintenance);
- _mav_put_uint16_t(buf, 36, generator_speed);
- _mav_put_int16_t(buf, 38, rectifier_temperature);
- _mav_put_int16_t(buf, 40, generator_temperature);
- _mav_finalize_message_chan_send(chan, MAVLINK_MSG_ID_GENERATOR_STATUS, buf, MAVLINK_MSG_ID_GENERATOR_STATUS_MIN_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_CRC);
- #else
- mavlink_generator_status_t packet;
- packet.status = status;
- packet.battery_current = battery_current;
- packet.load_current = load_current;
- packet.power_generated = power_generated;
- packet.bus_voltage = bus_voltage;
- packet.bat_current_setpoint = bat_current_setpoint;
- packet.runtime = runtime;
- packet.time_until_maintenance = time_until_maintenance;
- packet.generator_speed = generator_speed;
- packet.rectifier_temperature = rectifier_temperature;
- packet.generator_temperature = generator_temperature;
- _mav_finalize_message_chan_send(chan, MAVLINK_MSG_ID_GENERATOR_STATUS, (const char *)&packet, MAVLINK_MSG_ID_GENERATOR_STATUS_MIN_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_CRC);
- #endif
- }
- /**
- * @brief Send a generator_status message
- * @param chan MAVLink channel to send the message
- * @param struct The MAVLink struct to serialize
- */
- static inline void mavlink_msg_generator_status_send_struct(mavlink_channel_t chan, const mavlink_generator_status_t* generator_status)
- {
- #if MAVLINK_NEED_BYTE_SWAP || !MAVLINK_ALIGNED_FIELDS
- mavlink_msg_generator_status_send(chan, generator_status->status, generator_status->generator_speed, generator_status->battery_current, generator_status->load_current, generator_status->power_generated, generator_status->bus_voltage, generator_status->rectifier_temperature, generator_status->bat_current_setpoint, generator_status->generator_temperature, generator_status->runtime, generator_status->time_until_maintenance);
- #else
- _mav_finalize_message_chan_send(chan, MAVLINK_MSG_ID_GENERATOR_STATUS, (const char *)generator_status, MAVLINK_MSG_ID_GENERATOR_STATUS_MIN_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_CRC);
- #endif
- }
- #if MAVLINK_MSG_ID_GENERATOR_STATUS_LEN <= MAVLINK_MAX_PAYLOAD_LEN
- /*
- This variant of _send() can be used to save stack space by re-using
- memory from the receive buffer. The caller provides a
- mavlink_message_t which is the size of a full mavlink message. This
- is usually the receive buffer for the channel, and allows a reply to an
- incoming message with minimum stack space usage.
- */
- static inline void mavlink_msg_generator_status_send_buf(mavlink_message_t *msgbuf, mavlink_channel_t chan, uint64_t status, uint16_t generator_speed, float battery_current, float load_current, float power_generated, float bus_voltage, int16_t rectifier_temperature, float bat_current_setpoint, int16_t generator_temperature, uint32_t runtime, int32_t time_until_maintenance)
- {
- #if MAVLINK_NEED_BYTE_SWAP || !MAVLINK_ALIGNED_FIELDS
- char *buf = (char *)msgbuf;
- _mav_put_uint64_t(buf, 0, status);
- _mav_put_float(buf, 8, battery_current);
- _mav_put_float(buf, 12, load_current);
- _mav_put_float(buf, 16, power_generated);
- _mav_put_float(buf, 20, bus_voltage);
- _mav_put_float(buf, 24, bat_current_setpoint);
- _mav_put_uint32_t(buf, 28, runtime);
- _mav_put_int32_t(buf, 32, time_until_maintenance);
- _mav_put_uint16_t(buf, 36, generator_speed);
- _mav_put_int16_t(buf, 38, rectifier_temperature);
- _mav_put_int16_t(buf, 40, generator_temperature);
- _mav_finalize_message_chan_send(chan, MAVLINK_MSG_ID_GENERATOR_STATUS, buf, MAVLINK_MSG_ID_GENERATOR_STATUS_MIN_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_CRC);
- #else
- mavlink_generator_status_t *packet = (mavlink_generator_status_t *)msgbuf;
- packet->status = status;
- packet->battery_current = battery_current;
- packet->load_current = load_current;
- packet->power_generated = power_generated;
- packet->bus_voltage = bus_voltage;
- packet->bat_current_setpoint = bat_current_setpoint;
- packet->runtime = runtime;
- packet->time_until_maintenance = time_until_maintenance;
- packet->generator_speed = generator_speed;
- packet->rectifier_temperature = rectifier_temperature;
- packet->generator_temperature = generator_temperature;
- _mav_finalize_message_chan_send(chan, MAVLINK_MSG_ID_GENERATOR_STATUS, (const char *)packet, MAVLINK_MSG_ID_GENERATOR_STATUS_MIN_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN, MAVLINK_MSG_ID_GENERATOR_STATUS_CRC);
- #endif
- }
- #endif
- #endif
- // MESSAGE GENERATOR_STATUS UNPACKING
- /**
- * @brief Get field status from generator_status message
- *
- * @return Status flags.
- */
- static inline uint64_t mavlink_msg_generator_status_get_status(const mavlink_message_t* msg)
- {
- return _MAV_RETURN_uint64_t(msg, 0);
- }
- /**
- * @brief Get field generator_speed from generator_status message
- *
- * @return [rpm] Speed of electrical generator or alternator. UINT16_MAX: field not provided.
- */
- static inline uint16_t mavlink_msg_generator_status_get_generator_speed(const mavlink_message_t* msg)
- {
- return _MAV_RETURN_uint16_t(msg, 36);
- }
- /**
- * @brief Get field battery_current from generator_status message
- *
- * @return [A] Current into/out of battery. Positive for out. Negative for in. NaN: field not provided.
- */
- static inline float mavlink_msg_generator_status_get_battery_current(const mavlink_message_t* msg)
- {
- return _MAV_RETURN_float(msg, 8);
- }
- /**
- * @brief Get field load_current from generator_status message
- *
- * @return [A] Current going to the UAV. If battery current not available this is the DC current from the generator. Positive for out. Negative for in. NaN: field not provided
- */
- static inline float mavlink_msg_generator_status_get_load_current(const mavlink_message_t* msg)
- {
- return _MAV_RETURN_float(msg, 12);
- }
- /**
- * @brief Get field power_generated from generator_status message
- *
- * @return [W] The power being generated. NaN: field not provided
- */
- static inline float mavlink_msg_generator_status_get_power_generated(const mavlink_message_t* msg)
- {
- return _MAV_RETURN_float(msg, 16);
- }
- /**
- * @brief Get field bus_voltage from generator_status message
- *
- * @return [V] Voltage of the bus seen at the generator, or battery bus if battery bus is controlled by generator and at a different voltage to main bus.
- */
- static inline float mavlink_msg_generator_status_get_bus_voltage(const mavlink_message_t* msg)
- {
- return _MAV_RETURN_float(msg, 20);
- }
- /**
- * @brief Get field rectifier_temperature from generator_status message
- *
- * @return [degC] The temperature of the rectifier or power converter. INT16_MAX: field not provided.
- */
- static inline int16_t mavlink_msg_generator_status_get_rectifier_temperature(const mavlink_message_t* msg)
- {
- return _MAV_RETURN_int16_t(msg, 38);
- }
- /**
- * @brief Get field bat_current_setpoint from generator_status message
- *
- * @return [A] The target battery current. Positive for out. Negative for in. NaN: field not provided
- */
- static inline float mavlink_msg_generator_status_get_bat_current_setpoint(const mavlink_message_t* msg)
- {
- return _MAV_RETURN_float(msg, 24);
- }
- /**
- * @brief Get field generator_temperature from generator_status message
- *
- * @return [degC] The temperature of the mechanical motor, fuel cell core or generator. INT16_MAX: field not provided.
- */
- static inline int16_t mavlink_msg_generator_status_get_generator_temperature(const mavlink_message_t* msg)
- {
- return _MAV_RETURN_int16_t(msg, 40);
- }
- /**
- * @brief Get field runtime from generator_status message
- *
- * @return [s] Seconds this generator has run since it was rebooted. UINT32_MAX: field not provided.
- */
- static inline uint32_t mavlink_msg_generator_status_get_runtime(const mavlink_message_t* msg)
- {
- return _MAV_RETURN_uint32_t(msg, 28);
- }
- /**
- * @brief Get field time_until_maintenance from generator_status message
- *
- * @return [s] Seconds until this generator requires maintenance. A negative value indicates maintenance is past-due. INT32_MAX: field not provided.
- */
- static inline int32_t mavlink_msg_generator_status_get_time_until_maintenance(const mavlink_message_t* msg)
- {
- return _MAV_RETURN_int32_t(msg, 32);
- }
- /**
- * @brief Decode a generator_status message into a struct
- *
- * @param msg The message to decode
- * @param generator_status C-struct to decode the message contents into
- */
- static inline void mavlink_msg_generator_status_decode(const mavlink_message_t* msg, mavlink_generator_status_t* generator_status)
- {
- #if MAVLINK_NEED_BYTE_SWAP || !MAVLINK_ALIGNED_FIELDS
- generator_status->status = mavlink_msg_generator_status_get_status(msg);
- generator_status->battery_current = mavlink_msg_generator_status_get_battery_current(msg);
- generator_status->load_current = mavlink_msg_generator_status_get_load_current(msg);
- generator_status->power_generated = mavlink_msg_generator_status_get_power_generated(msg);
- generator_status->bus_voltage = mavlink_msg_generator_status_get_bus_voltage(msg);
- generator_status->bat_current_setpoint = mavlink_msg_generator_status_get_bat_current_setpoint(msg);
- generator_status->runtime = mavlink_msg_generator_status_get_runtime(msg);
- generator_status->time_until_maintenance = mavlink_msg_generator_status_get_time_until_maintenance(msg);
- generator_status->generator_speed = mavlink_msg_generator_status_get_generator_speed(msg);
- generator_status->rectifier_temperature = mavlink_msg_generator_status_get_rectifier_temperature(msg);
- generator_status->generator_temperature = mavlink_msg_generator_status_get_generator_temperature(msg);
- #else
- uint8_t len = msg->len < MAVLINK_MSG_ID_GENERATOR_STATUS_LEN? msg->len : MAVLINK_MSG_ID_GENERATOR_STATUS_LEN;
- memset(generator_status, 0, MAVLINK_MSG_ID_GENERATOR_STATUS_LEN);
- memcpy(generator_status, _MAV_PAYLOAD(msg), len);
- #endif
- }
|